Intel庐 Server Specialist Certification Exam
Question No: 111
As an Intel庐 ServerSpecialist, you are educating your customer on the benefits of server management in their solution selling. Having finally understood how this will help to add valueto the business and for their customers you must explain how to enable the KVM for the BMCin the Grantley generation server? Please choose your answer from the list below.
-
Install the RMMx full
-
Activate the KVM in the BMC GUI with a software key
-
Install the KVM module
-
Install the RMMx lite
-
Install the RMMx
Answer: D
Question No: 112
Which of the following is the MOST robust RAID level with 4 HDDs?
-
RAID 0
-
RAID 5
-
RAID 6
-
RAID 10
Answer: C
Question No: 113
As an Intel庐 Server Specialist, you need to advise your customer on a proposed server configuration; your customer would like to know what the differences are between the Intel庐 Server Board S2600WT2 and the Intel庐 Server Board S2600WTT. How would you answer from the list below?
-
More powerful CPU support
-
More memory is supported
-
More PCIe devices support
-
2U chassis support
-
2 Integrated 10Gb ports
Answer: E
Question No: 114
Your customer is looking for a Server System which will support two high-end GPGPU cards. As the Intel庐 Server Specialistwhich of the following server systems would you recommend? (Select ALL that apply).
-
Intel庐 Server System P4308RPLSHDR
-
Intel庐 Server System H2216XXKR2 and HNS2600KP
-
Intel庐 Server System P4304CR2LFKN
-
Intel庐 Server System P4308RPLSHDR
-
Intel庐Server Chassis P4304XXMUXX and board S2600CW2
Answer: C,E
Question No: 115
A customer asks which technologies are supported in Intel庐 Server Chipsets. How should an Intel庐 Server Specialist respond from the following options?
-
Intel庐 Virtualisation Technology for Directed I/O
-
Intel庐 Virtualisation Technology for Connectivity
-
Intel庐Virtualisation Technology for Routing
-
Virtual Machine Device Queues
Answer: A
Question No: 116
Your customer has asked you to enable BMC management and remote access. They are now asking you to walk them through the different features which are available via the Embedded Web Server. They would like to see what the current power draw of the server is. Please choose all the correct answers from the list below:
-
Configuration Tab, Node Manager and Power Monitor
-
System Information Tab and power monitor
-
Server Health Tab and Power statistics
-
System Information Tab, FRU Information and Power Monitor
Answer: C
Question No: 117
Your customer has a dual socket server board; and they have complained to you that their customer is constantly getting PCIe errors. At yourrequest they send you the System Event log. On investigation of the SEL by you, you discover some events that look like the
following:
TimeStamp:03/05/2014 12:18:41 SensorName:PCIe Cor Sensor. Bus:0, device:3, function:2
Which one of the following represents the correct order in which troubleshooting should occur?
-
If error happens very rarely, disable AER reporting in BIOS
-
Check SEL troubleshooting guide in order to understand PCIe bus, device, function of the card that generates the error. Then check TPS to identify the slot to find the suspect component.
-
List through the error codes from the User guide to find the translation table for the SEL in order to identify the failing device and link speed.
-
Force slower PCIe link speeds in the BIOS setup utility.
-
If the error happens regularly, try to cross-test PCIe devices to see if the error follows the card or stays with the slot.
-
Rerun the FRU/SDR to force the system to detect the correct PCIe generation for this device.
-
A, B, E
-
A, D, C
-
A, F, E
-
B, C, F
Answer: A
Question No: 118
Your customer is asking you as an Intel庐 Server Specialist for some clarification on RAID arrays on the Grantley generation of server products. In particular they need to know which RAID levels can be achieved on S2600CW2S. How would you advise your customer from the list below?
A. 0, 1, 1E
B. 0, 1, 1E, 10, 5 through the updgrade key AXXRPFKHY5
C. 0, 1, 10, 5, 6
D. 0, 1, 1E, 10, 5, 50 through the upgrade key AXXRPFKHY5
E. 0, 1, 10, 5
Answer: D
Question No: 119
Which of the following steps can be used to restore the default setting ofthe Intel庐 server BIOS? (Select ALL that apply).
-
Jumper select system into BIOS configuration mode
-
Standard System BIOS Update
-
Enter BIOS setup, Load Default values in Exit Page, select Save Changes
-
Clear the CMOS
-
Run the command Syscfg /rfs
-
Enter BIOS Setup, Press F9, and then F10
Answer: C,D,F
Question No: 120
Why is it important to update the system BIOS when building a new server?
-
Updating the BIOS causes the fan speed control to be set correctly for a chassis.
-
Updating the BIOS configures the BMC settings for remote access.
-
Updating the BIOS implements the latest updates and fixes for a system.
-
Updating the BIOS ensures the BMC and HSC have a clear communication path.
Answer: C